Glossary entry

English term or phrase:

bonded neutral

French translation:

neutre relié

Added to glossary by Benoit Cambron
Aug 17, 2017 15:34
6 yrs ago
6 viewers *
English term

bonded neutral

English to French Tech/Engineering Electronics / Elect Eng
If you are connecting your generator to a panel board transfer switch, a licensed electrician will need to consider removing the bonded neutral to ensure proper operation of household GFCI circuits.
Proposed translations (French)
3 +1 neutre relié
4 +3 neutre connecté à la terre

Discussion

Johannes Gleim Aug 18, 2017:
@ Benoît is the neutral bonded to the housing additionally to thè terminals?

Proposed translations

+1
17 mins
Selected

neutre relié

Suggestion
Peer comment(s):

agree GILLES MEUNIER : tout à fait, ce n'est pas grounded neutral
11 hrs
Merci
Something went wrong...
4 KudoZ points awarded for this answer. Comment: "Merci Alain. For the technically inclined: http://ezgeneratorswitch.com/need-know-generator-type-bonded-floating-neutral/"
+3
3 hrs

neutre connecté à la terre

"According to the North American electrical code (US and Canada), Neutral and Safety Ground must be bonded at the service entrance (or main breaker panel). The green wilre will also be connected to Earth via a ground rod driven into the earth near the service entrance. Neutral will also be grounded at the power pole and distribution transformer.

All this grounding ensures that the AC wiring is kept near earth potential, and won't drift up to 12 KV due to a fault in the distribution transformer."
https://electronics.stackexchange.com/questions/120940/why-a...

"XL PRO³ calcul | Legrand
http://www.legrand.be/fr/xlprocalcul/info
TT (neutre et masses connectés séparément à la terre); TN (neutre connecté à la terre, masses connectées au neutre, conducteurs N et PE séparés ou ..."
Peer comment(s):

agree Tony M : Yes, it has to be understood as 'earth-bonded neutral'; perhaps 'relié', in line with common technical usage?
5 hrs
agree Daryo
14 hrs
agree Eric KUATE FOTSO
15 hrs
neutral Johannes Gleim : No RCD will trigger in case of leakage fault if an earthed neutral or PE is connected to the device. The neutral has to be unearthed! The PEN must be split into PE (bonded to the enclosure) and N upstream of the RCD.
1 day 2 hrs
Something went wrong...